Facebook Instagram Youtube Twitter

Detection of Neutrons

neutron detection
Generally every type of neutron detector must be equipped with converter and one of the conventional radiation detectors.
Source: large.stanford.edu

Detection of neutrons is very specific since the neutrons are electrically neutral particles. Thus they are mainly subject to strong nuclear forces but not to electric forces. Therefore neutrons are not directly ionizing, and they usually have to be converted into charged particles before they can be detected. Generally, every type of neutron detector must be equipped with a converter (to convert neutron radiation to common detectable radiation) and one of the conventional radiation detectors (scintillation detector, gaseous detector, semiconductor detector, etc.).

Neutron Converters

Two basic types of neutron interactions with matter are for this purpose available:

  • Elastic scattering. The free neutron can be scattered by a nucleus, transferring some kinetic energy to the nucleus. If the neutron has enough energy to scatter off nuclei, the recoiling nucleus ionizes the material surrounding the converter. Only hydrogen and helium nuclei are light enough for practical application. The conventional detector can collect charges produced in this way to produce a detected signal. Neutrons can transfer more energy to light nuclei. This method is appropriate for detecting fast neutrons (fast neutrons do not have a high cross-section for absorption), allowing the detection of fast neutrons without a moderator.
  • Neutron absorption. This is a common method allowing the detection of neutrons of the entire energy spectrum. This method is based on various absorption reactions (radiation capture, nuclear fission, rearrangement reactions, etc.). The neutron is absorbed by target material (converter), emitting secondary particles such as protons, alpha particles, beta particles, photons (gamma rays), or fission fragments. Some reactions are threshold reactions (requiring minimum energy of neutrons), but most reactions occur at epithermal and thermal energies. That means the moderation of fast neutrons is required leading to poor energy information of the neutrons. The most common nuclei for the neutron converter material are:
    • 10B(n,α). Where the neutron capture cross-section for thermal neutrons is σ = 3820 barns, and the natural boron has an abundance of 10B 19,8%.
    • 3He(n,p). Where the neutron capture cross-section for thermal neutrons is σ = 5350 barns, and the natural helium has an abundance of 3He 0.014%.
    • 6Li(n,α). Where the neutron capture cross-section for thermal neutrons is σ = 925 barns, and the natural lithium has an abundance of 6Li 7,4%.
    • 113Cd(n,ɣ). Where the neutron capture cross-section for thermal neutrons is σ = 20820 barns, and the natural cadmium has an abundance of 113Cd 12,2%.
    • 235U(n,fission). Where the fission cross-section for thermal neutrons is σ = 585 barns, and the natural uranium has an abundance of 235U 0.711%. Uranium as a converter produces fission fragments which are heavy charged particles. This has a significant advantage. The heavy charged particles (fission fragments) create a high output signal because the fragments deposit a large amount of energy in a detector-sensitive volume. This allows easy discrimination of the background radiation (e.i. gamma radiation). For example, this important feature can be used in a nuclear reactor power measurement, where a significant gamma background accompanies the neutron field.

Detection of Thermal Neutrons

Thermal neutrons are in thermal equilibrium with a surrounding temperature of 290K (17 °C or 62 °F). Most probable energy at 17°C (62°F) for Maxwellian distribution is 0.025 eV (~2 km/s). This part of the neutron’s energy spectrum constitutes the most important spectrum in thermal reactors.

Thermal neutrons have a different and often much larger effective neutron absorption cross-section (fission or radiative capture) for a given nuclide than fast neutrons.

In general, there are many detection principles and many types of detectors. In nuclear reactors, gaseous ionization detectors are the most common since they are very efficient, reliable and cover a wide range of neutron flux. Various types of gaseous ionization detectors constitute so-called the excore nuclear instrumentation system (NIS). The excore nuclear instrumentation system monitors the reactor’s power level by detecting neutron leakage from the reactor core.

Detection of Neutrons using Ionization Chamber

Ionization chambers are often used as the charged particle detection device. For example, if the inner surface of the ionization chamber is coated with a thin coat of boron, the (n, alpha) reaction can occur. Most of (n,alpha) reactions of thermal neutrons are 10B(n,alpha)7Li reactions accompanied by 0.48 MeV gamma emission.(n,alpha) reactions of 10B

Moreover, isotope boron-10 has a high (n, alpha) reaction cross-section along the entire neutron energy spectrum. The alpha particle causes ionization within the chamber, and ejected electrons cause further secondary ionizations.

Another method for detecting neutrons using an ionization chamber is to use the gas boron trifluoride (BF3) instead of air in the chamber. The incoming neutrons produce alpha particles when they react with the boron atoms in the detector gas. Neutrons in a nuclear reactor can be detected by using either method. It must be noted, BF3 counters are usually operated in the proportional region.

Fission Chamber – Wide Range Detectors

fission chamber - detection of neutronsFission chambers are ionization detectors used to detect neutrons. Fission chambers may be used as the intermediate-range detectors to monitor neutron flux (reactor power) at the intermediate flux level. They also provide indications, alarms, and reactor trip signals. The design of this instrument is chosen to provide overlap between the source range channels and the full span of the power range instruments.

In the case of fission chambers, the chamber is coated with a thin layer of highly enriched uranium-235 to detect neutrons.  Neutrons are not directly ionizing, and they usually have to be converted into charged particles before they can be detected. A thermal neutron will cause an atom of uranium-235 to fission, with the two fission fragments produced having high kinetic energy and causing ionization of the argon gas within the detector. One advantage of using uranium-235 coating rather than boron-10 is that the fission fragments have much higher energy than the alpha particle from a boron reaction. Therefore fission chambers are very sensitive to neutron flux, and this allows the fission chambers to operate in higher gamma fields than an uncompensated ion chamber with boron lining.

Activation Foils and Flux Wires

Neutrons may be detected using activation foils and flux wires. This method is based on neutron activation, where an analyzed sample is first irradiated with neutrons to produce specific radionuclides. The radioactive decay of these produced radionuclides is specific for each element (nuclide). Each nuclide emits the characteristic gamma rays, measured using gamma spectroscopy, where gamma rays detected at particular energy indicate a specific radionuclide and determine concentrations of the elements.

Selected materials for activation foils are, for example:

  • indium,
  • gold,
  • rhodium,
  • iron,
  • aluminum,
  • niobium.

These elements have large cross-sections for the radiative capture of neutrons. The use of multiple absorber samples allows characterization of the neutron energy spectrum. Activation also allows the recreation of a historic neutron exposure.  Commercially available criticality accident dosimeters often utilize this method. By measuring the radioactivity of thin foils, we can determine the amount of neutrons to which the foils were exposed.

Flux wires may be used in nuclear reactors to measure reactor neutron flux profiles. Principles are the same. Wire or foil is inserted directly into the reactor core and remains in the core for the required time for activation to the desired level. After activation, the flux wire or foil is rapidly removed from the reactor core, and the activity is counted. Activated foils can also discriminate energy levels by placing a cover over the foil to filter out (absorb) certain energy level neutrons. For example, cadmium is widely used to absorb thermal neutrons in a thermal neutron filter.

Detection of Fast Neutrons

Fast neutrons are neutrons of kinetic energy greater than 1 MeV (~15 000 km/s). In nuclear reactors, these neutrons are usually named fission neutrons. The fission neutrons have a Maxwell-Boltzmann energy distribution with mean energy (for 235U fission) of 2 MeV. Inside a nuclear reactor, the fast neutrons are slowed down to thermal energies via a process called neutron moderation. These neutrons are also produced by nuclear processes such as nuclear fission or (ɑ,n) reactions.

In general, there are many detection principles and many types of detectors. But it must be added that detecting fast neutrons is a very sophisticated discipline since fast neutrons cross-sections are much smaller than in the energy range for slow neutrons. Fast neutrons are often detected by first moderating (slowing) them to thermal energies. However, during that process, the information on the original energy of the neutron, its direction of travel, and the time of emission is lost.

Proton Recoil – Recoil Detectors

The most important type of detectors for fast neutrons are those that directly detect recoil particles, particularly recoil protons resulting from elastic (n, p) scattering. Only hydrogen and helium nuclei are light enough for practical application.  In the latter case, the recoil particles are detected in a detector. Neutrons can transfer more energy to light nuclei. This method is appropriate for detecting fast neutrons allowing detection of fast neutrons without a moderator. This method allows the neutron’s energy to be measured together with the neutron fluence, i.e., the detector can be used as a spectrometer. Typical fast neutron detectors are liquid scintillators, helium-4 based noble gas detectors, and plastic detectors (scintillators). For example, plastic has a high hydrogen content. Therefore, it is useful for fast neutron detectors when used as a scintillator.

Bonner Spheres Spectrometer

There are several methods for detecting slow neutrons and few methods for detecting fast neutrons. Therefore, one technique for measuring fast neutrons is to convert them to slow
neutrons and then measure the slow neutrons. One of the possible methods is based on Bonner spheres. The method was first described in 1960 by Ewing and Tom W. Bonner and employed thermal neutron detectors (usually inorganic scintillators such as 6LiI) embedded in moderating spheres of different sizes.  Bonner spheres have been used widely to measure neutron spectra with neutron energies ranging from thermal up to at least 20 MeV. A Bonner sphere neutron spectrometer (BSS) consists of a thermal-neutron detector, polyethylene spherical shells, and two optional lead shells of various sizes. A 3He detector or inorganic scintillators such as 6LiI can be used to detect thermal neutrons. LiGlass scintillators are very popular for the detection of thermal neutrons. The advantage of LiGlass scintillators is their stability and their large range of sizes.

Detection of Neutrons using Scintillation Counter

Scintillation counters are used to measure radiation in various applications, including hand-held radiation survey meters, personnel and environmental monitoring for radioactive contamination, medical imaging, radiometric assay, nuclear security, and nuclear plant safety. They are widely used because they can be made inexpensively yet with good efficiency and can measure the intensity and the energy of incident radiation.

Scintillation counters can be used to detect alphabetagamma radiation. They can also be used for the detection of neutrons. For these purposes, different scintillators are used.

  • Neutrons. Since the neutrons are electrically neutral particles, they are mainly subject to strong nuclear forces but not electric forces. Therefore neutrons are not directly ionizing, and they usually have to be converted into charged particles before they can be detected. Generally, every type of neutron detector must be equipped with a converter (to convert neutron radiation to common detectable radiation) and one of the conventional radiation detectors (scintillation detector, gaseous detector, semiconductor detector, etc.).  Fast neutrons (>0.5 MeV) primarily rely on the recoil proton in (n,p) reactions. Materials rich in hydrogen, for example, plastic scintillators, are therefore best suited for their detection. Thermal neutrons rely on nuclear reactions such as the (n,γ) or (n,α) reactions to produce ionization. Materials such as LiI(Eu) or glass silicates are therefore particularly well-suited for detecting thermal neutrons. The advantage of 6LiGlass scintillators is their stability and their large range of sizes.

See previous:

Application of Neutrons

See above:

Neutron

See next:

Shielding of Neutrons