Residual Heat

Residual heat is the energy produced or transferred in the reactor core after its shutdown when the nuclear chain reaction is stopped. The amount of decay heat production after shutdown is directly given by the power history.

In general, sources of residual heat are usually classified into four categories:

  • Accumulated Heat
  • Residual Nuclear Power
  • Decay Heat
  • Pump Heat

This branch of nuclear engineering is of the highest importance in reactor safety since it explains the question:

Why can’t we just turn off nuclear reactors?

Why do reactors have to be cooled for long periods while the chain reaction can be stopped almost immediately?

Answer:

An additional energy source known as decay heat contributes to thermal power in power operation but dominates in shutdown mode. Decay heat is the heat released due to radioactive decay of fission products accumulated in the fuel. To understand the processes after reactor shutdown, we have to explain the term “residual heat”.

Decay Heat - Nuclear Power - Thermal Power

Residual Heat

The fission reaction is responsible for the power generated in a nuclear reactor at power operation. The fission reaction rate is proportional to the neutron flux, so you might expect that thermal power output is proportional to nuclear power. The relationship between flux and thermal power, however, is not linear.

Nuclear Power - Decay Heat
Thermal energy sources in power operation of pressurized water reactor

In other words, after the reactor trip, the nuclear power drops almost immediately since the chain reaction is stopped almost immediately. On the other hand, the thermal power decreases more slowly, for example, due to decay heat production. In this case, the thermal power output is not, by no means, proportional to nuclear power.

See also: Thermal Power vs. Nuclear Power

In general, sources of these non-linearities that contribute to the residual heat are usually classified into four categories:

  • Accumulated Heat
  • Residual Nuclear Power
  • Decay Heat
  • Pump Heat
Accumulated Heat
In power operation, the fuel and all structural materials contain huge amounts of accumulated heat. Note that the central region of fuel pellets can reach up to 1000°C. After the reactor shutdown, also this heat must be transferred into the reactor coolant. This component of residual heat dominates in the first seconds after shutdown but disappears after about 30 seconds.
Residual Nuclear Power
prompt drop - negative reactivity-minAfter a large negative reactivity addition, the neutron level undergoes a rapid decrease of about two decades (prompt drop) until it is at the level of production of delayed neutrons. But even if it were possible to insert an infinite negative reactivity, the neutron flux would not immediately fall to zero. Prompt neutrons will be absorbed almost immediately. After the prompt drop, the neutron flux continues to fall according to a stable period. The shortest negative stable period that originates from the last group of delayed neutrons is τe = – 1/λ1 = -80s. The neutron flux cannot be reduced more rapidly than this period. On the other hand, the prompt drop causes an immediate drop to about 6% of rated power. Within a few tens of seconds, the thermal power that originates from nuclear fission is below the thermal power that originates from decay heat.
Pump Heat
Generally, reactor coolant pumps are very powerful, they can consume up to 6 MWe each. About two-thirds of its power input appears as heat, known as pump heat, in the reactor coolant (about 16 MWth) as long as the reactor coolant pumps are operated. Heat is generated by fluid friction in the turbulent flow and depends on the fluid viscosity and the flow rate. This flow is forced just by reactor coolant pumps.

Decay Heat

Energy release per fission

In a nuclear reactor, the average recoverable energy per fission is about 200 MeV, being the total energy minus the energy of the energy of antineutrinos that are radiated away. About 6 percent of the 200 MeV produced by average fission is released with a delay at some time after the instant of fission. This energy comes from the beta and gamma decay of fission products and transuranic elements accumulated in the fuel rather than directly from the fission process itself. Most of these fission products are highly unstable (radioactive) and undergo further radioactive decays to stabilize themselves. On average, after each U-235 fission, the neutron-rich fission fragments must undergo 6 negative beta decays (6 neutrons must decay to 6 protons). Absorption of this radiation in the fuel generates a significant amount of heat even when a reactor is shut down.

Fission essentially ceases when a reactor is shut down, but decay energy is still being produced. The energy produced after shutdown is referred to as decay heat. The amount of decay heat production after shutdown is directly influenced by the reactor’s power history (fission products accumulation) prior to shutdown and the fuel burnup level (actinides accumulation – especially in case of spent fuel handling). A reactor operated at full power for 10 days prior to the shutdown has much higher decay heat generation than a reactor operated at low power for the same period. On the other hand, when the reactor changes its power from 50% to 100% of full power, the ratio of decay heat to neutron power drops to roughly half its previous level. It builds up slowly as the fission product inventory adjusts to the new power.

Decay HeatThe decay heat produced after a reactor shutdown from full power is initially equivalent to 6 to 7% of the rated thermal power. Since radioactive decay is a random process at the level of single atoms, it is governed by the radioactive decay law. Note that irradiated nuclear fuel contains many different isotopes that contribute to decay heat, all subject to the radioactive decay law. Therefore a model describing decay heat must consider decay heat to be a sum of exponential functions with different decay constants and initial contribution to the heat rate. Fission fragments with a short half-life are much more radioactive (at the time of production) and contribute significantly to decay heat but will lose their share rapidly. On the other hand, fission fragments and transuranic elements with a long half-life are less radioactive (at the time of production) and produce less decay heat but will lose their share more slowly. This decay heat generation rate diminishes to about 1% approximately one hour after shutdown. The decay comes from the beta and gamma decay of fission products and transuranic elements (+ alpha decay).

  • The energy of delayed β decay. About 6 MeV of fission energy is in the form of the kinetic energy of electrons (beta particles). The fission fragments are neutron-rich nuclei, and therefore they usually undergo beta decay to stabilize themselves. Beta particles deposit their energy essentially in the fuel element, within about 1 mm of the fission fragment.
  • The energy of delayed gamma decay. Gamma rays usually accompany beta decay, and the gamma rays are well attenuated by high-density and high Z materials. In a reactor core, the largest share of the energy will be deposited in the fuel containing uranium dioxide. Still, a significant share of the energy will also be deposited in the fuel cladding and the coolant (moderator). The range of gamma rays in a reactor varies according to the initial energy of the gamma-ray. It can be stated that most of the gammas in a reactor have a range from 10cm – 1m.

Classification according to the source material:

  • Decay of fission products. Decay of fission products dominates source directly after shutdown and in periods up to years.
  • Decay of actinides produced by radiative capture (especially 239Pu). Decay of 239Pu and 240Pu is the dominating source from the long-term point of view (e.g., units or up to tens of years after shutdown – depending on the fuel burnup). 239Pu itself decays via alpha decay into 235U with a half-life of 24 100 years. It significantly depends on the fuel burnup, and it determines conditions for spent fuel handling. (See also: Fuel Depletion)
  • Decay of activated structural materials by radiative capture. Decay of activated structural materials is a minor contributor to overall decay heat.

See also: ANSI/ANS-5.1-2014, Decay Heat Power in Light Water Reactors. American Nuclear Society, 2014.

However, even at these low levels (about 1% after one hour), the amount of heat generated requires the continued removal of heat for an appreciable time after shutdown. Decay heat is a long-term consideration and impacts spent fuel handling, reprocessing, waste management, and reactor safety.

The reactor’s design must allow for removing this decay heat from the core by some means. If adequate heat removal is not available, decay heat will increase the temperatures in the core to the point that fuel melting and core damage will occur, as in the case of Three Mile Island and Fukushima. The degree of concern with decay heat will vary according to reactor type and design. Therefore, there is little concern about core temperature due to decay heat for low power, pool-type reactors.

Decay Heat Removal

Methods for removing decay or residual heat from a reactor core can be grouped into two general categories:

  • Closed-Loop System. One category includes methods that circulate fluid through the reactor core in a closed-loop, using a heat exchanger to transfer heat out of the system.
    • Heat Removal through Steam Generators. Steam generators can be and are usually used to remove decay heat from a reactor, and they dissipate heat directly to the main condenser or the atmospheric steam dump system. In this operational mode, some reactor coolant pumps (RCPs) must usually be in operation, or natural circulation must have remained.
    • Heat Removal through RHR. The residual heat removal system (RHR) is a low-pressure heat removal system. PWRs take water from one or two RCS hot legs, cool it in RHR heat exchangers, and pump it back to the cold legs or core flooding tank nozzles. To accomplish RHR heat removal, RHR heat exchangers transfer heat to the component cooling water or service water system, which then transports heat to the ultimate heat sink (UHS).
  • Open System: The other category includes methods that operate in an open system, drawing in cool fluid from some source and discharging warmer fluid to some storage area or the environment.
    • Decay heat removal using the feed-and-bleed method. The feed-and-bleed method for decay heat removal becomes a necessary method in some pressurized water reactors (PWRs) if there is a loss of steam generator heat sink capability. The feed-and-bleed technique involves passing hot coolant out of the primary system through a pilot-operated relief valve (PORV) while simultaneously feeding the primary system with subcooled coolant through a high-pressure safety injection system (HPSI), which is part of the emergency core cooling system.

Calculation of Decay Heat – Wigner-Way formula

The amount of decay heat being generated in a fuel assembly at any time after shutdown can be exactly calculated by the determination of the number of fission products present at the time of shutdown. This is a fairly detailed process and is dependent upon power history. The concentrations, decay energies, and half-lives of fission products are known for a given type of fuel. By starting from a known value, based on power history at shutdown, the decay heat generation rate can be calculated for any time after shutdown. An exact solution must consider the fact that hundreds of different radionuclides are present in the core, each with its concentration and decay half-life. For this purpose, the SCALE/TRITON code can be used for depletion calculations. The SCALE/ORIGEN-ARP code can be used to calculate decay heat rates at specific initial fuel composition and discharge burnup levels.

See also: Brian J. Ade, Ian C. Gauld. Decay Heat Calculations for PWR and BWR Assemblies Fueled with Uranium and Plutonium Mixed Oxide Fuel Using Scale,  ORNL/TM-2011/290, OAK RIDGE NATIONAL LABORATORY, 2011.

It is also possible to make a rough approximation by using a single half-life representing the core’s overall decay over a certain period. An equation that uses this approximation is the Wigner-Way formula:

wigner-way formula - equation

where

  • Pd(t) = thermal power generation due to beta and gamma rays,
  • P0 = thermal power before the shutdown,
  • t0 = time, in seconds, of thermal power level before the shutdown,
  • t = time, in seconds, elapsed since the shutdown.
 
References:
Nuclear and Reactor Physics:
  1. J. R. Lamarsh, Introduction to Nuclear Reactor Theory, 2nd ed., Addison-Wesley, Reading, MA (1983).
  2. J. R. Lamarsh, A. J. Baratta, Introduction to Nuclear Engineering, 3d ed., Prentice-Hall, 2001, ISBN: 0-201-82498-1.
  3. W. M. Stacey, Nuclear Reactor Physics, John Wiley & Sons, 2001, ISBN: 0- 471-39127-1.
  4. Glasstone, Sesonske. Nuclear Reactor Engineering: Reactor Systems Engineering, Springer; 4th edition, 1994, ISBN: 978-0412985317
  5. W.S.C. Williams. Nuclear and Particle Physics. Clarendon Press; 1 edition, 1991, ISBN: 978-0198520467
  6. G.R.Keepin. Physics of Nuclear Kinetics. Addison-Wesley Pub. Co; 1st edition, 1965
  7. Robert Reed Burn, Introduction to Nuclear Reactor Operation, 1988.
  8. U.S. Department of Energy, Nuclear Physics and Reactor Theory. DOE Fundamentals Handbook, Volume 1 and 2. January 1993.
  9. Paul Reuss, Neutron Physics. EDP Sciences, 2008. ISBN: 978-2759800414.

Advanced Reactor Physics:

  1. K. O. Ott, W. A. Bezella, Introductory Nuclear Reactor Statics, American Nuclear Society, Revised edition (1989), 1989, ISBN: 0-894-48033-2.
  2. K. O. Ott, R. J. Neuhold, Introductory Nuclear Reactor Dynamics, American Nuclear Society, 1985, ISBN: 0-894-48029-4.
  3. D. L. Hetrick, Dynamics of Nuclear Reactors, American Nuclear Society, 1993, ISBN: 0-894-48453-2. 
  4. E. E. Lewis, W. F. Miller, Computational Methods of Neutron Transport, American Nuclear Society, 1993, ISBN: 0-894-48452-4.

See above:

Reactor Operation